Wiki source code of CY 01 Contingency Overview

Version 3.3 by Ryan Larkin on 2017/08/07 16:00

Show last authors
1 **Washington County Sheriff's Office**
2
3 **CORRECTIONS DIVISION**
4
5 Policy Manual
6
7
8 Volume: CY
9
10 Contingency Management
11
12 Chapter: 01
13
14 Contingency Overview
15
16
17 Replaces and/or Supersedes:
18
19 PK 01, PK 02, OD 03-001-A, CY 11 2009-06-22
20
21 Published:
22
23 01/23/2012
24
25 Review Date:
26
27 01/09/2017
28
29
30 Sheriff Cory C. Pulsipher
31
32 Chief Deputy Jake Schultz
33
34
35 **__TABLE OF CONTENTS__**
36
37 CY 01_101 Definitions
38
39 CY 01_102 References
40
41 CY 01_103 General
42
43 CY 01_104 Distribution of Plans
44
45 CY 01_105 Communication
46
47 CY 01_106 Utilities
48
49 CY 01_107 Utility Off
50
51 CY 01_108 Utility On
52
53 CY 01_109 Documentation
54
55 CY 01_110 Emergency Equipment Testing
56
57 CY 01_111 Debriefing
58
59 CY 01_112 Evacuation and Alternative Containment
60
61 CY 01_113 Fire, Natural Disaster, Explosion, or Bomb Threat
62
63 CY 01_114 Inmate Disturbance
64
65 CY 01_115 Hostage Situation
66
67 CY 01_116 Escape and Escape Attempt
68
69 CY 01_117 Emergency Transport
70
71 CY 01_118 Civil Disturbance
72
73 CY 01_119 Inmate Death and Advance Directives
74
75 CY 01_120 Pandemic
76
77
78 **CY 01_101 __DEFINITIONS__**
79
80 1. WCSO: Washington County Sheriff's Office
81 1. PCF: Purgatory Correctional Facility
82 1. IPP: Inmate Programs and Placement
83 1. UDC: Utah Department of Corrections
84 1. State Inmate: An inmate being held under contract with the UDC.
85
86 **CY 01_102 __REFERENCES__**
87
88 1. Immigration and Customs Enforcement Standards:
89 11. 2000-25.
90 1. Utah Sheriffs' Association Jail Standards:
91 11. F06.01.01: Content: Emergency Response
92 11. F06.02.01: Emergency Plans
93 11. F06.02.02: Evacuation Plans
94 11. F06.02.03: Distribution of Plans
95
96 **CY 01_103 __GENERAL__**
97
98 1. Policy:
99 11. There should be written policies and procedures covering the various emergency situations which might be encountered in the operation of the jail facility. The policies and procedures relating to emergencies should include, but not be limited to:
100 111. Exigencies requiring evacuation of all or part of the inmate population;
101 111. Fires;
102 111. Inmate disturbances;
103 111. Hostage situations;
104 111. Escapes and escape attempts;
105 111. Chemical spills or contamination;
106 111. Disruption of utilities or communications systems.
107 111. Civil disturbances; and
108 111. Natural disasters, including but not limited to:
109 1111. Floods;
110 1111. Earthquakes; and
111 1111. Weather-related emergencies.
112 11. Tactical plans should be adopted and implemented to provide employees with understandable and readily available strategies for responding to exigencies.
113 11. Inmates should not be permitted control or authority over other inmates.
114 11. Staff should protect inmates from person abuse, corporal punishment, personal injury, disease, property damage, and harassment.
115 11. Staff and inmates should receive necessary medical treatment during and after an incident, when possible and appropriate due to incident circumstances.
116 11. At least three days worth of food and drinking/cooking water shall be maintained for employees and inmates.
117 1. Rationale:
118 11. Written policies and procedures are necessary to ensure that employees are prepared during emergency situations.
119 11. Effective response to emergency situations in jails is demanding at best, but may be an extremely difficult and high-risk process without prior planning.
120
121 **CY 01_104 __DISTRIBUTION OF PLANS__**
122
123 1. Policy:
124 11. Emergency plans should have controlled and restricted access to prevent them from being compromised by inmates and others; however, employees should be provided sufficient information and training to ensure that they can function effectively in the event of an emergency.
125 1. Rationale:
126 11. The need to prevent the compromise of emergency plans should not be carried to such an extreme that staff have inadequate preparation and training for emergencies.
127
128 **CY 01_105 __COMMUNICATION__**
129
130 1. Policy:
131 11. All emergency incidents shall be reported to the Sheriff as soon as possible via proper chain of command.
132 11. Emergency incidents involving State Inmates requires notification to IPP and UDC Control One as soon as possible.
133 11. The Corrections Chief Deputy or designee shall determine if and when the facility may return to normal operations.
134 11. Communication with the press should be deferred to the Corrections Chief Deputy or other designated public relations representative.
135 1. Rationale:
136 11. Proper and timely notifications are necessary in order to initiate additional resource response.
137 11. Unauthorized communication with the public could have negative results.
138
139 **CY 01_106 __UTILITIES__**
140
141 1. Policy:
142 11. Electricity shall be shutoff in the event of:
143 111. Electrical emergency;
144 111. Flood;
145 111. Gas leak;
146 111. Other natural disaster, such as an earthquake, where the utility is likely to have been compromised.
147 11. The gas system shall be shutoff in the event of:
148 111. Electrical emergency;
149 111. Fire;
150 111. Gas leak;
151 111. Other natural disaster, such as an earthquake, where the utility is likely to have been compromised.
152 11. The water system shall be shutoff in the event of:
153 111. Electrical emergency;
154 111. Flood;
155 111. Other natural disaster, such as an earthquake, where the utility is likely to have been compromised.
156 111. When a utility system is turned off or on, the Corrections Chief Deputy and the WCSO Maintenance Department shall be notified.
157 1. Rationale:
158 11. Systematic reactive steps may help prevent or mitigate personal injury or facility damage.
159
160 **CY 01_107 __UTILITY OFF__**
161
162 1. Policy:
163 11. Utility systems may be shutoff by any PCF employee. All PCF employees shall receive training on how to properly shutoff the electrical, gas, and water utility systems.
164 11. Utility systems should not be shutoff without reason.
165 11. A facility-wide announcement should be made prior to turning off a utility system.
166 1. Rationale:
167 11. Waiting for a specific individual to shutoff a utility system could produce or amplify adverse effects including personal injury and facility damage.
168 11. Turning utility systems off without a reason could unnecessarily cause system damage, facility damage, personal injury, or operational inconvenience.
169 11. An announcement prior to turning off a utility system could help to avoid system damage, facility damage, personal injury, or operational inconvenience.
170 1. Procedure:
171 11. Electricity:
172 111. There are two sources of electrical power for the PCF facility: standard and back-up.
173 111. Before the standard electrical power is shutoff, the back-up generator should first be shutoff. The generator is located outside the East end of the facility and within the secure exterior perimeter. There is one switch to shutoff the generator. This switch is located behind the West side panel. It is the left of two rocker switches. This rocker switch must be placed into the center “STOP” position.
174 111. In order to shutoff the standard source of electrical power for the entire facility, two switches must be turned off. They are both located inside the Main Electrical Room at the East end of the facility. This room can only be accessed from outside the facility. The first switch (ELECTRICAL MAIN-A) is located near the bottom of the the first panel on the right as you enter the room. The second switch (ELECTRICAL MAIN-B) is located along the same wall but at the far (left) end.
175 11. Gas:
176 111. There is one valve that will shutoff the natural gas line into the facility. This valve is marked “GAS MAIN.” It is located outside the Northwest corner of the Sallyport garage. If it is not possible to safely reach this valve, the gas company should be contacted to shutoff the gas lines from a street location.
177 111. Individual appliances, such as water boilers, each have an off valve at the gas line to the appliance.
178 11. Water:
179 111. There are two water systems in the facility: Standard and fire suppression sprinklers.
180 111. The standard water system has one off valve. It is located inside the PCF Sallyport garage, in the Northwest corner. There is a four-inch vertical pipe from the ground that turns horizontal shortly thereafter. Near this junction is a horizontal valve with a handle about twelve inches long labeled “WATER MAIN.” By turning this handle perpendicular with the pipe, the water will be turned off.
181 111. The fire suppression sprinkler system is split into two areas of coverage: (1) Central; and (2) Max and Booking. The off valves for both areas are located inside the Sallyport garage near the Northwest corner. There is a large horizontal pipe that splits into two large, vertical, parallel pipes. At each pipe junction, there is a small, blue, wheel valve; a large, blue, wheel valve; and a large, yellow, tamper indicator switch. The large, blue, wheel valves are the shutoff valves. The wheels need to be turned clockwise in order to shutoff the water supply.
182
183 **CY 01_108 __UTILITY ON__**
184
185 1. Policy:
186 11. Utility systems should only be returned to the on function:
187 111. By a trained individual;
188 111. After the reason for the utility system being shutoff has been remedied; and
189 111. After an announcement has been made to provide notice of the action.
190 11. Rationale:
191 111. The guidelines above could help prevent or mitigate system damage, facility damage, or personal injury.
192 11. Procedure:
193 111. In order to turn a utility system back on, the switch or valve identified in the previous section should be reversed.
194
195 **CY 01_109 __DOCUMENTATION__**
196
197 1. Policy:
198 11. All emergency situations related to the jail shall be documented in the jail computer system.
199 11. Any time that a utility system is shutoff or turned back on, the event should be documented in the jail computer system log. The event should be logged as a passdown (PSD) and should include the date, time, and reason.
200 1. Rationale:
201 11. A written record memorializes events.
202 11. Accurate details of events may be required at a later time.
203
204 **CY 01_110 __EMERGENCY EQUIPMENT TESTING__**
205
206 1. Policy:
207 11. Emergency equipment will be tested on a regular basis as follows:
208 111. Generator:
209 1111. Visual Inspection Weekly
210 1111. Power Tested Monthly
211 1111. Load Tested Annually
212 1111. Inspected Semi-Annually by outside contractor
213 111. Emergency Lighting:
214 1111. Tested Monthly
215 111. Alarms:
216 1111. Tested Monthly
217 11. Washington County Maintenance Personel will be responsible for maintaning a log of tests conducted.
218 1. Rationale:
219 11. Regular testing of emergency equipment is necessary to ensure it's functionality in the event of an actual event.
220
221 **CY 01_111 __DEBRIEFING__**
222
223 1. Policy:
224 11. After each emergency situation has concluded, a debriefing should be conducted by the Sheriff or designee.
225 1. Rationale:
226 11. Post-emergency debriefings are a tool for discovering and correcting problems with policies, procedures, implementation of procedures, incident management, and individual performance.
227
228 **CY 01_112 __EVACUATION AND ALTERNATIVE CONTAINMENT__**
229
230 Reference policy [[CY 02 Evacuation and Alternative Containment>>doc:Policy.Corrections.CY 02 Evacuation and Alternative Containment.WebHome]].
231
232
233 **CY 01_113 __FIRE, NATURAL DISASTER, EXPLOSION, OR BOMB THREAT__**
234
235 Reference policy [[CY 03 Fire, Natural Disaster, Explosion, or Bomb Threat>>doc:Policy.Corrections.CY 03 Fire, Natural Disaster, Explosion, or Bomb Threat.WebHome]].
236
237
238 **CY 01_114 __INMATE DISTURBANCE__**
239
240 Reference policy[[ CY 04 Inmate Disturbance>>doc:Policy.Corrections.CY 04 Inmate Disturbance.WebHome]].
241
242
243 **CY 01_115 __HOSTAGE SITUATION__**
244
245 Reference policy [[CY 05 Hostage Situation>>doc:Policy.Corrections.CY 05 Hostage Situation.WebHome]].
246
247
248 **CY 01_116 __ESCAPE OR ESCAPE ATTEMPT__**
249
250 Reference policy [[CY 06 Escape or Escape Attempt>>doc:Policy.Corrections.CY 06 Escape or Escape Attempt.WebHome]].
251
252
253 **CY 01_117 __EMERGENCY TRANSPORT__**
254
255 Reference policy [[CY 07 Inmate Transportation Contingency>>doc:Policy.Corrections.CY 07 Inmate Transportation Contingency.WebHome]].
256
257
258 **CY 01_118 __CIVIL DISTURBANCE__**
259
260 Reference policy [[CY 08 Civil Disturbance>>doc:Policy.Corrections.CY 08 Civil Disturbance.WebHome]].
261
262
263 **CY 01_119 __INMATE DEATH AND ADVANCE DIRECTIVES__**
264
265 Reference policy [[CY 09 Inmate Death and Advance Directives>>doc:Policy.Corrections.Cy 09 Inmate Death and Advance Directives.WebHome]].
266
267
268 **CY 01_120 __PANDEMIC__**
269
270 Reference policy: [[CY 10 Disease Pandemic>>doc:Policy.Corrections.CY 10 Disease Pandemic.WebHome]].